Description

• Steel sheet enclosure, white painted; internal components made of EPP.
• Inlet and outlet duct connection ports compatible with nominal diameters of 100 mm and 125 mm.
• 2 x EC brushless motors, each coupled to a centrifugal impeller; 3 speeds.
• High-efficiency counter-flow type heat exchanger.
• Mechanical automatic by-pass, 100% filtered.
• Advanced electronic suite, easily accessible for first setting and ordinary maintenance operations; functions offered:
• operating parameters setting (fan speed, relative humidity threshold, etc.),
• automatic management of the by-pass,
• no-frost protection of the heat exchanger,
• automatic management of the (optional) pre-heater, if installed,
• operation at Vmax inhibition in a pre-set time slot, which can be set at installation (QUIET function); a back-up battery ensures constant updating of the time marked by the clock (RTC - Real Time Clock), even in case of power failure,
• possibility to automatically switch to Vmax, linking it to bathroom lighting (BOOST ROOM LIGHT function),
• possibility of managing the automatic switch to a reduced speed (30% less than Vmin), useful to grant the correct air exchange during the long absence of occupants, also limiting consumption (HOLIDAY function),
• filter status monitoring: the need for cleaning / maintenance is shown on the remote control panel display,
• possibility of connection to a presence sensor (PIR), able to automatically manage the switch to Vmax,
• 2 x ISO COARSE 45% (G3) filters, on extracted air (stale) and on (fresh) air supply; ISO COARSE 65% (G4) filter for extraction port, ePM10 50% (M5), ePM1 55% (F7) and ePM1 80% (F9) filters for supply port are available as optional.
• Condensate collection vessel with overflow protection.
Read full descriptionClose description

Certifications

Energy label Energy label

Technical Data Sheet

  • Filter class on extract
    ISO COARSE 45% (G3)
  • Filter class on supply
    ISO COARSE 45% (G3)
  • Frequency (Hz)
    50
  • Insulation class
  • IP
    X2
  • Max absorbed current at Max speed (A)
    0,65
  • Max absorbed current at Min speed (A)
    0,30
  • Motor class
    B
  • Nominal diameter (m)
    100/125
  • Nominal power at Max speed (W)
    64
  • Nominal power at Min speed (W)
    16
  • Number of phases (Ph)
    1
  • Voltage (V)
    220-240
  • Weight (Kg)
    14
  • Airflow at 1st speed (l/s)
    13,9
  • Airflow at 1st speed (m³/h)
    50
  • Breakout sound power LWA [dB(A)]
    53
  • Breakout sound pressure at 3m at Max speed Lp [dB (A)]
    36
  • Max airflow at Max speed (l/s)
    33,3
  • Max airflow at Max speed (m³/h)
    120
  • Max pressure (mmH2O)
    38,2
  • Max pressure (Pa)
    375
  • Max RPM
    3900
  • Max thermal efficiency (%)
    87,0
  • Min RPM
    1830
  • Sound power at exhaust inlet LWA [dB(A)]
    53
  • Sound power at supply outlet LWA [dB(A)]
    69
  • Sound pressure at 3m at Max speed at extraction side Lp [dB (A)]
    35
  • Sound pressure at 3m at Max speed at supply side Lp [dB (A)]
    52
  • Size A (mm)
    484
  • Size B (mm)
    440,5
  • Size C (mm)
    218
  • Size D (mm)
    40
  • Size E (mm)
    5
  • Size F (mm)
    250
  • Size G (mm)
    158
  • Size H (mm)
    69
  • Size I (mm)
    69
  • Size J (mm)
    92
  • Size K (mm)
    333
  • Size L (mm)
    513
  • Size M (mm)
    361
Curva_JPG_12219-Curve_per_Catalogo

Accessories

Discover accessories related to the product

FTR G3 206X132X5
FTR G3 206X132X5
Filter, class ISO Coarse 45% (G3), for heat recovery units. Dimensions: 206x132x5 mm.
FTR G4 206X132X5
FTR G4 206X132X5
Filter, class ISO Coarse 65% (G4), for heat recovery units. Dimensions: 206x132x5 mm.
FTR M5 208X127X25
FTR M5 208X127X25
Filter, class ePM10 50% (M5), for heat recovery units. Dimensions: 208x127x25 mm.
FTR F7 208X127X25
FTR F7 208X127X25
Filter, class ePM1 55% (F7), for heat recovery units. Dimensions: 208x127x25 mm.
FTR F9 208X127X25
FTR F9 208X127X25
Filter, class ePM1 80% (F9), for heat recovery units. Dimensions: 208x127x25 mm.
C SMOKE
C SMOKE
Environmental sensor for air quality.
C HCS
C HCS
Environmental sensor for relative humidity control.
AH 125 (RISCALDATORE ARIA)
AH 125 (RISCALDATORE ARIA)
Duct heater
• To be installed in the ventilation system, always after the fan, and/or the noise attenuator/air filter
• Suitable for single phase and three p...
ELECTRIC HEATER 500
ELECTRIC HEATER 500
CB TOUCH LCD W
CB TOUCH LCD W
Remote control panel with color graphic LCD display that can be combined with VORTICE centralized residential heat recovery units. TECHNICAL FEATURES: • Graphic touch display...