Description

• Centrifugal roof fan suitable for extracting hot fumes at up to 400 °C for 120 minutes.
• Base manufactured from phosphated pressed steel, epoxy powder coated with hammered effect finish, guaranteeing long-term resistance to atmospheric agents.
• Aerodynamically contoured inlet port for optimum performance, fashioned as a single unit with the base and gauged to optimize air flow.
• Motor mounting plate made of steel with galvanization surface treatment.
• Protective cap carried by top plate made of steel with galvanization surface treatment.
• Cold outside air drawn into a cooling chamber made of pressed steel with polyester powder coated and oven baked hammered effect finish, colour grey.
• Pressed steel motor cover: pickled and phosphated surface, polyester powder coated and oven baked finish, colour grey, with hammered texture.
• Accident prevention and anti-bird grilles (to UNI ISO 13857 standard), consisting of electrically welded steel rings with epoxy powder coated finish, colour black.
• Centrifugal impeller with self-cleaning backward curved blades, dynamically balanced (UNI ISO 1940, Point 1 – Class 6.3), made of electrolytically galvanized steel.
• Dahlander 2 speed three-phase AC motor with shaft turning in ball bearings, size to UNEL MEC standard, flange B5, self-ventilating. Motor insulation class H, with metal cooling fan and cable gland.
• Minimum air flow 8200 m3/h.
• Maximum air flow: 9200 m3/h.
• Galvanized steel eye lugs for transport and lifting/handling operations.
• Cable guaranteeing continuity of earth connection.
• Steel safety wire for anchoring appliances once installed.
• Vortice speed controller.
Read full descriptionClose description

Certifications

torrette_tr_ed_v_ambiente01
torrette_tr_ed_v_ambiente02
torrette_tr_ed_v_ambiente03

Technical Data Sheet

  • Frequency (Hz)
    50
  • Insulation class
  • Max absorbed current at Max speed (A)
    2,00
  • Max absorbed current at Min speed (A)
    1,30
  • Max absorbed power at Max speed (W)
    810
  • Max ambient temperature for continuous operation (°C)
    90
  • Motor ATEX marking
    55
  • Nominal diameter (mm)
    500
  • Number of phases (Ph)
    3
  • Number of poles
    8
  • Power absorbed at 1st speed (W)
    700
  • Voltage (V)
    400
  • Weight (Kg)
    217
  • Airflow at 1st speed (l/s)
    2278
  • Airflow at 1st speed (m³/h)
    8200
  • Max airflow at Max speed (l/s)
    2556
  • Max airflow at Max speed (m³/h)
    9200
  • Max pressure at Max speed (mmH20)
    34
  • Max pressure at Max speed (Pa)
    334
  • Max RPM
    720
  • Min RPM
    610
  • Pressure at 1st speed (mmH20)
    28
  • Pressure at 1st speed (Pa)
    275
  • Sound pressure Lp [dB (A)] at 3 m
    71
  • Dimension Q (mm)
    12
  • Dimension R (mm)
    50
  • Size A (mm)
    1462
  • Size B (mm)
    980
  • Size C (mm)
    900
  • Size D (mm)
    1010
  • Size E (mm)
    595
  • Size F (mm)
    38
  • Size G (mm)
    40
  • Size H (mm)
    923
  • Size L (mm)
    465
  • Size M (mm)
    472
  • Size N (mm)
    715
quota
Curva_JPG_15175-Curve_per_Catalogo
Interested?
If you are interested in this product, contact us or locate your nearest Vortice dealer.
Documentation
You can see all the documentation relating to this product: price list, information booklet and wiring diagram.

Accessories

Discover accessories related to the product

TR-G 100/150/180/210 6-8P(GRIGLI APROT.)
TR-G 100/150/180/210 6-8P(GRIGLI APROT.)
Intake port protection grille for use when the unit is mounted within reach.
TR-CU 100/150/180/210 6-8P(CONTROT.BASE)
TR-CU 100/150/180/210 6-8P(CONTROT.BASE)
Installation base counter-frame.
TR-CVT
TR-CVT
Single-phase speed controller with 3-position selector (0 – 1 – 2).
IRT 35
IRT 35
• Three-phase speed controller
IRET 6
IRET 6
• Three-phase electronic speed controller
IRET INVERTER 2.2
IRET INVERTER 2.2
Three-phase speed controller INVERTER.
IRET INVERTER 2,5 M
IRET INVERTER 2,5 M
Three-phase speed controller
GV2 ME06
GV2 ME06
Thermal-Magnetic motor circuit breaker for ATEX industrial fans.
GV2 ME07
GV2 ME07
Thermal-Magnetic motor circuit breaker for ATEX industrial fans.
TR-G 70/100 (GRIGLIA DI PROTEZIONE)
TR-G 70/100 (GRIGLIA DI PROTEZIONE)
Intake port protection grille for use when the unit is mounted within reach.
TR-CU 70/100    (CONTROTELAIO DI BASE U)
TR-CU 70/100 (CONTROTELAIO DI BASE U)
Installation base counter-frame.
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info