Heat recovery units equipped with rotary heat exchangers

Description

• Frames consisting of rounded aluminium profiles with built-in, polyamide made, spacers for class TB2 thermal break; corners made of reinforced polyamide; double skin (sandwich), 10/10 panels (inner side with galvanized steel sheet, outer side with pre-laquered metal sheet (RAL 7035) with protective film); insulation through 50 mm high density (M0) mineral wool.
• 2 EC motors, independently adjustable, external rotor type, integrating safety thermal cut-outs, with backward curved impellers directly driven by ball bearings; 2 speeds adjustable during the installation.
• Air-to-air, rotary, aluminium made heat exchanger whose high performance, certified by Eurovent, exceeds 80% according to EN 308 standard.
• Circular branch connections with lip seals to grant the system air tightness.
• Electric post-heaters integrated.
• 2 filters, respectively G4 on extracted air (stale) and F7 on (fresh) air supply, both mounted upstream of inner components, on runners fitted with lip seals to ensure effective air tightness.
• Access to filters and inner components by security latch on removable panels.
• Technical compartment grouping electrical components and regulation. Open access by panels mounted on hinges.
• Brackets crimped into the structure for fixing to the ground.
• Rotation sensor, integrated in the machine control, showing the wheel working status.
• Pressure switch that controls the airflow across each fan, showing possible faults on the control panel display.
• Advanced electronic control suite, including a control box enriched by a LCD touch-screen display allowing:
o To independently adjust the fan speeds,
o To set a weekly, holiday and public holiday timer,
o To control the status of both filters,
o To integrate the unit in a BMS (communication protocols supported are MODBUS, BACNET and WEB TCP-IP),
o To adjust operating mode and performances, optimizing energy provision.
o To set the unit operation mode in case of fire, to be allowed among 5 pre-defined fan control alternatives,
o The machine diagnostic.
• A podlockable local circuit breaker, mounted on front panel, allows to stop the unit in case of fault.
Read full descriptionClose description

Certifications


Technical Data Sheet

  • Filter class for extract air
    G4
  • Filter class for supply air
    F7
  • Frequency (Hz)
    50
  • Max ambient temperature for continuous operation (°C)
    40
  • Min ambient temperature for continuous operation (°C)
    -20
  • Motor Class
    B
  • Motor IP protection
    54
  • Motor Power (W)
    750X2
  • Nominal Diameter (mm)
    400
  • Number of Phases (Ph)
    3+N
  • Power pre-heater
    10,5
  • Protection current
    18,5
  • Voltage (V)
    400
  • Weight (Kg)
    278
  • Delivery max (m³/h)
    2300
  • Sound power level - radiated Lw [dB(A)]
    70
  • Supplier's name or trade mark
    Vortice
  • Nominal NRVU flow rate [m3/s]
    0,3800
  • Effective electic power input [kW]
    0,770
  • Potenza elettrica assorbita effettiva [KW]
    0,770
  • Portata nominale [m3/s]
    0,3800
  • Supplier's name or trade mark:
    Vortice
  • Declared typology:
    UVNR-B
  • Declared typology
    UVNR-B
  • Type of drive
    con variatore di velocità: VSD
  • Type of drive:
    con variatore di velocità: VSD
  • Type of heat recovery system HRS:
    altro
  • Type of heat recovery system HRS
    altro
  • Thermal efficiency of heat recovery [%]
    79,8
  • Efficienza termica del recupero di calore [%]
    79,8
  • SFPint [W/m3/s]
    1365
  • SFPint [W/m3/s]
    1365
  • Face velocity at design flow rate [m/s]
    1,28
  • Face velocity at design flow rate [m/s]:
    1,28
  • Pressione esterna nominale (?ps, ext) [Pa]
    642
  • Nominal external pressure (?ps, ext) [Pa]
    642
  • Internal pressure drop of ventilation components (?ps,int) [Pa]
    191
  • Caduta di pressione interna dei componenti della ventilazione (?ps, int) [Pa]
    191
  • Caduta di pressione interna dei componenti estranei alla ventilazione (?ps, add) [Pa]
    NA
  • Internal pressure drop of non-ventilation components (?ps,add) [Pa]
    NA
  • Static efficiency of fans used in accordance with Regulation (EU) No 327/2011 [%]
    49,0
  • Efficienza statica dei ventilatori usati secondo Regolamento 327/2011/UE [%]
    49,0
  • Declared maximum internal leakage rate of the casing of ventilation units [%]:
    NA
  • Declared maximum internal leakage rate of the casing of ventilation units [%]
    NA
  • Declared maximum external leakage rate of the casing of ventilation units [%]
    2,7
  • Declared maximum external leakage rate of the casing of ventilation units [%]:
    2,7
  • Energy performance energy or classification of the filters:
    NA
  • Energy performance energy or classification of the filters
    NA
  • Description of visual filter warning:
    Vedi libretto istruzioni
  • Description of visual filter warning
    Vedi libretto istruzioni
  • Casing sound power level (LWA) [dB(A)]:
    70
  • Casing sound power level (LWA) [dB(A)]
    70
  • Size A (mm)
    1500
  • Size B (mm)
    830
  • Size C (mm)
    1220
  • Vents diameter Ø A (mm)
    355
Interested?
If you are interested in this product, contact us or locate your nearest Vortice dealer.
Documentation
You can see all the documentation relating to this product: price list, information booklet and wiring diagram.

Accessories

Discover accessories related to the product

TOUCH LCD CP
TOUCH LCD CP
Control panel with touch LCD display
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info