Description

• Material: UV resistant plastic (prevents ageing caused by exposure to sunlight).
• Nominal diameter 100 mm
• Three-phase EC brushless motor of external rotor type with shaft turning in ball bearings, designed to guarantee notably low energy consumption and to provide 3 different air flow rates (the first two of which can be selected at the moment of installation)
• Air flow between 11.7 m3/h and 42 m3/h
• The appliance is equipped with an electronic circuit board and relative humidity sensor, allowing it to switch automatically from a previously set minimum air flow rate to the maximum setting. The pcb incorporates an electronic timer that shuts off the motor automatically when relative humidity returns below the threshold value. The timer setting is selectable during installation in the range 3’-20’ (default setting 3’).
Read full descriptionClose description

Certifications


Technical Data Sheet

  • Absorbed power 1st speed (W)
    2,1
  • Frequency (Hz)
    50
  • Insulation Class
    II°
  • IP
    X4
  • Max ambient temperature for continuous operation (°C)
    50
  • Max. absorbed Current at max. speed (A)
    0,037
  • Max. absorbed Current at min. speed (A)
    0,028
  • Max. absorbed power at max speed (W)
    6,4
  • Nominal Diameter (mm)
    100
  • Voltage (V)
    220-230
  • Weight (Kg)
    0,8
  • Delivery 1st speed (l/s)
    3,3
  • Delivery 1st speed (m³/h)
    11,7
  • Max delivery at max speed (l/s)
    11,7
  • Max delivery at max speed (m³/h)
    42
  • Pressure - 1st speed (mmH20)
    2,4
  • Pressure - 1st speed (Pa)
    23,5
  • Pressure max - max speed (mmH20)
    8,8
  • Pressure max - max speed (Pa)
    86,3
  • Sound pressure level Lp in free field [dB(A)] 3 m max speed
    17.3
  • Sound pressure level Lp in free field [dB(A)] 3 m min speed
    10.1
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption class SEC in average climate zone
    NA
  • Specific Energy Consumption class SEC average [kWh/m2a]
    -6,2
  • Specific Energy Consumption class SEC cold [kWh/m2a]
    -19,5
  • Specific Energy Consumption class SEC warm [kWh/m2a]
    1,5
  • Declared typology
    UVR-U: unidirezionale
  • Type of drive
    NA
  • Type of heat recovery system HRS
    assente
  • Thermal efficiency of heat recovery at reference air flow [%]
    NA
  • Maximum flow rate [m3/h]
    43
  • Electric power input of the fan drive, including any motor control equipment, at maximum flow rate [W]
    3,5
  • Sound power level LWA [dB(A)]
    32.4
  • Reference flow rate [m3/s]
    0,0084
  • Reference pressure difference [Pa]
    62
  • SPI [W/(m3/h)]
    0,22591
  • Control factor CTRL
    1
  • Control typology
    manuale
  • Maximum internal leakage rates [%]
    NA
  • Maximum external leakage rates [%]
    NA
  • Mixing rate
    NA
  • Position and description of visual filter warning
    NA
  • Airflow sensitivity to pressure variations at + 20Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/a]
    311
  • AHS average Annual heating saved [kWh primary energy/a]
    1397
  • AHS cold Annual heating saved [kWh primary energy/a]
    8901
  • AHS warm Annual heating saved [kWh primary energy/a]
    632
  • Size A (mm)
    194,6
  • Size B (mm)
    182
  • Size C (mm)
    171
  • Size D (mm)
    164
  • Size E (mm)
    97,8
  • Size F (mm)
    129
  • Size G (mm)
    40,5
  • Size H (mm)
    22,2
  • Size I (mm)
    8
Interested?
If you are interested in this product, contact us or locate your nearest Vortice dealer.
Documentation
You can see all the documentation relating to this product: price list, information booklet and wiring diagram.
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info