BACK
Code 11590

VORT HR 350 EXO

Wall-mounting residencial heat recovery unit designed for outdoor installation

Description

• Zinc-coated pressed steel enclosure; interior lined with sound-absorbent and fire-resistant material (DIN 13501)
• Duct connection ports of nominal diameter 150 mm.
• 2 x EC brushless motor with shaft turning in ball bearings, each coupled to a backward curved centrifugal impeller; 3 speeds, selectable independently at the moment of installation.
• Air flow settable between 115 m3/h and 350 m3/h.
• Ultra high-efficiency counter-flow type heat exchanger fashioned from moulded plastic (PS).
• Automatically activated system designed to prevent icing of the heat exchanger.
• 2 x F5 filter (alternatively, option of F7 filter on outlet duct)
• Blocked filter status monitoring system
• Brackets for wall-mounted installation
Read full descriptionClose description

Certifications

  • CE CE
Energy label Energy label

Technical Data Sheet

  • Absorbed Current max (A)
    1,2
  • Absorbed Power max (W)
    140
  • Frequency (Hz)
    50
  • Insulation Class
  • IP
    X2
  • Max ambient temperature for continuous operation (°C)
    50
  • Voltage (V)
    230
  • Weight (Kg)
    38
  • Delivery max (l/s)
    97,2
  • Delivery max (m³/h)
    350
  • Pressure max (mmH2O)
    40
  • Pressure max (Pa)
    392
  • Sound power level - radiated Lw [dB(A)]
    56,5
  • Sound power level exhaust inlet Lw [dB(A)]
    31,2
  • Sound power level supply outlet Lw [dB(A)]
    53,9
  • Sound pressure level air extraction Lp in free field [dB (A)] 3m - max speed
    10,7
  • Sound pressure level air supply Lp in free filed [dB (A)] 3m - max speed
    33,4
  • Sound pressure level radiated Lp in free filed [dB (A)] 3m - max speed
    36,0
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption class SEC in average climate zone
    A+
  • Specific Energy Consumption class SEC average [kWh/m2a]
    -42,3
  • Specific Energy Consumption class SEC cold [kWh/m2a]
    -81,2
  • Specific Energy Consumption class SEC warm [kWh/m2a]
    -17,4
  • Declared typology
    UVR-B: bidirezionale
  • Type of drive
    variatore di velocità: VSD
  • Type of heat recovery system HRS
    a recupero
  • Thermal efficiency of heat recovery at reference air flow [%]
    89,9
  • Maximum flow rate [m3/h]
    284
  • Electric power input of the fan drive, including any motor control equipment, at maximum flow rate [W]
    66,0
  • Sound power level LWA [dB(A)]
    57
  • Reference flow rate [m3/s]
    0,0556
  • Reference pressure difference [Pa]
    50
  • SPI [W/(m3/h)]
    0,15500
  • Control factor CTRL
    0,85
  • Control typology
    amb. centralizzato
  • Maximum internal leakage rates [%]
    15,5
  • Maximum external leakage rates [%]
    8,2
  • Mixing rate
    NA
  • Position and description of visual filter warning
    Vedi libretto istruzioni
  • Airflow sensitivity to pressure variations at + 20Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/a]
    185
  • AHS average Annual heating saved [kWh primary energy/a]
    4627
  • AHS cold Annual heating saved [kWh primary energy/a]
    9052
  • AHS warm Annual heating saved [kWh primary energy/a]
    2092
  • Diametro Ø (mm)
    150
  • Size A (mm)
    704
  • Size B (mm)
    913
  • Size C (mm)
    429
  • Size D (mm)
    804
  • Size E (mm)
    100
  • Size F (mm)
    300
Interested?
If you are interested in this product, contact us or locate your nearest Vortice dealer.
Documentation
You can see all the documentation relating to this product: price list, information booklet and wiring diagram.

Accessories

Discover accessories related to the product

FTR F7 192X395X48
FTR F7 192X395X48
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info