Description

• Sheet steel housing, internally insulated, fire resistant according wit DIN EN 13501.
• High efficiency backward curved centrifugal fans driven by 3 speeds EC (brushless) motors.
• High efficiency plastic cross-counterflow heat exchanger.
• Automatic thermodynamic by-pass.
• Integrated frost protection.
• Nominal diameter of duct connections 125 mm.
• 2xM5 filters (F7 inlet filter available as option), easy to replace.
• Remote, wired control panel allowing:
o To Switch on/off the product
o To select the fan speeds
o To show the filters status
• Brackets for suspended installation.
Read full descriptionClose description

Certifications

Energy label Energy label

Technical Data Sheet

  • Absorbed Current max (A)
    1,0
  • Absorbed Power max (W)
    102
  • Frequency (Hz)
    50
  • Max ambient temperature for continuous operation (°C)
    40
  • Nominal Diameter (mm)
    125
  • Voltage (V)
    230
  • Weight (Kg)
    24
  • Delivery max (l/s)
    58,3
  • Delivery max (m³/h)
    210
  • Pressure max (mmH2O)
    48,4
  • Pressure max (Pa)
    475
  • Sound power level - radiated Lw [dB(A)]
    43,1
  • Sound power level exhaust inlet Lw [dB(A)]
    36,5
  • Sound power level supply outlet Lw [dB(A)]
    43,3
  • Sound pressure level air extraction Lp in free field [dB (A)] 3m - max speed
    16,0
  • Sound pressure level air supply Lp in free filed [dB (A)] 3m - max speed
    22,8
  • Sound pressure level radiated Lp in free filed [dB (A)] 3m - max speed
    22,6
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption class SEC in average climate zone
    A
  • Declared typology
    UVR-B: bidirezionale
  • Type of drive
    velocità multiple: VM
  • Type of heat recovery system HRS
    a recupero
  • Control factor CTRL
    0,85
  • Control typology
    amb. centralizzato
  • Specific Energy Consumption class SEC average [kWh/m2a]
    -36,3
  • Specific Energy Consumption class SEC cold [kWh/m2a]
    -74,7
  • Specific Energy Consumption class SEC warm [kWh/m2a]
    -11,7
  • Thermal efficiency of heat recovery at reference air flow [%]
    87,8
  • Maximum flow rate [m3/h]
    163
  • Electric power input of the fan drive, including any motor control equipment, at maximum flow rate [W]
    100,0
  • Sound power level LWA [dB(A)]
    43
  • Reference flow rate [m3/s]
    0,0317
  • Reference pressure difference [Pa]
    50
  • SPI [W/(m3/h)]
    0,39474
  • Maximum internal leakage rates [%]
    5,3
  • Maximum external leakage rates [%]
    4,5
  • Mixing rate
    NA
  • Position and description of visual filter warning
    Vedi libretto istruzioni
  • Airflow sensitivity to pressure variations at + 20Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/a]
    402
  • AHS average Annual heating saved [kWh primary energy/a]
    4570
  • AHS cold Annual heating saved [kWh primary energy/a]
    8940
  • AHS warm Annual heating saved [kWh primary energy/a]
    2067
  • Diametro Ø (mm)
    125
  • Size A (mm)
    860
  • Size B (mm)
    643
  • Size C (mm)
    240
  • Size D (mm)
    969
  • Size E (mm)
    551
Interested?
If you are interested in this product, contact us or locate your nearest Vortice dealer.
Documentation
You can see all the documentation relating to this product: price list, information booklet and wiring diagram.

Accessories

Discover accessories related to the product

FTR M5 227X212X24
FTR M5 227X212X24
FTR F7 227X212X24
FTR F7 227X212X24
FTR F7 228X224X24
FTR F7 228X224X24
F7 Filter
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info